Nixon's Universal Circuit Protection Range

We have made this page to display our range of circuit protection and give more infomation to make it easier for you to choose the correct product you need for you job.

Our range is simple, easy and well designed,

We have used handle colors to seperate different items as we stock a wide range of items.
Red Handle = Isolator / Main Switch
Blue Handle = C Curve & Standard everyday items, 30mA for RCD & RCBO's
Black Handle = D Curve Normally for motor start and industrial use
Green Handle = 10mA RCBO's Normally for medical use

If you have any feedback, good or bad, please let us know so we can keep expanding our range.

All these items listed have the same design pattern so they will all line up together.

For more information about ESV RCBO testing requirements please click here

NE-ISO
Isolator (NON AUTO)

Red Handle
Available in 1Pole, 2Pole, 3Pole

63AMP is designed to match all items up to 63AMP in size,
100/125AMP is designed to match NE-CB125 because of the larger design

Standard width per pole = 18mm

Main Purpose of item - Main Switch / Panel Isolator

RCM Printed onto Product, SAA Approval Certificate


NE-CB
Circuit Breaker - C Curve

Blue Handle - C Curve
Available in 1Pole, 2Pole, 3Pole
2, 6, 10, 16, 20, 25, 32, 40, 50, 63AMP
10kA Breaking Capacity

Standard width per pole = 18mm

Main Purpose of item - Overload / Short Circuit Protection

RCM Printed onto Product, SAA Approval Certificate


NE-CB
Circuit Breaker - D Curve

Black Handle - D Curve
Available in 1Pole, 2Pole, 3Pole
2, 6, 10, 16, 20, 25, 32, 40, 50, 63AMP
10kA Breaking Capacity

Standard width per pole = 18mm

Main Purpose of item - Overload / Short Circuit Protection

RCM Printed onto Product, SAA Approval Certificate


NE-CB125
Circuit Breaker up to 125AMP - C Curve

Blue Handle - C Curve
Available in 1Pole, 2Pole, 3Pole
63, 80, 100, 125AMP
10kA Breaking Capacity

Larger design than normal NE-CB
Width per pole = 27mm

Main Purpose of item - Overload / Short Circuit Protection

RCM Printed onto Product, SAA Approval Certificate

NE-CB125
Circuit Breaker up to 125AMP - D Curve

Black Handle - D Curve
Available in 1Pole, 2Pole, 3Pole
80, 100, 125AMP
10kA Breaking Capacity

Larger design than normal NE-CB
Width per pole = 27mm

Main Purpose of item - Overload / Short Circuit Protection

RCM Printed onto Product, SAA Approval Certificate

NE-RCD
Residual Current Device

Available in 2Pole & 4Pole
40AMP & 63AMP
30mA Standard Tripping Current

Matching design for NE-CB

Standard width 2Pole = 36mm
Standard width 4Pole = 72mm

Main Purpose of item - Earth Leakage Protection

RCM Printed onto Product, SAA Approval Certificate

NE-miniRCBO
RCBO in 1 Module Design - Combines RCD+CB - 30mA

Blue Handle - C Curve & 30mA
6, 10, 16, 20, 25, 32AMP
30mA Standard Tripping Current

Matching design for NE-CB

Standard width per pole = 18mm

Main Purpose of item - Overload / Short Circuit & Earth Leakage Protection

RCM Printed onto Product, SAA Approval Certificate
Meets ESV Additional Testing & verification requirements for RCBOs and listed on ESV website

NE-miniRCBO
RCBO in 1 Module Design - Combines RCD+CB 10mA

Green Handle - C Curve & 10mA
10, 16, 20, 25, 32AMP
10mA Standard Tripping Current

Matching design for NE-CB

Standard width per pole = 18mm

Main Purpose of item - Overload / Short Circuit & Earth Leakage Protection

RCM Printed onto Product, SAA Approval Certificate
Meets ESV Additional Testing & verification requirements for RCBOs and listed on ESV website

NE-RCBO2P
RCBO in 2 Module Design - Combines RCD+CB - C Curve

Blue Handle - C Curve
6, 10, 16, 20, 25, 32, 40AMP
30mA Standard Tripping Current

Matching design for NE-CB

Standard width = 36mm

Main Purpose of item - Overload / Short Circuit & Earth Leakage Protection

RCM Printed onto Product, SAA Approval Certificate
Meets ESV Additional Testing & verification requirements for RCBOs and listed on ESV website

NE-RCBO2P
RCBO in 2 Module Design - Combines RCD+CB - D Curve

Black Handle - D Curve
10, 16, 20, 25, 32, 40AMP
30mA Standard Tripping Current

Matching design for NE-CB

Standard width = 36mm

Main Purpose of item - Overload / Short Circuit & Earth Leakage Protection

RCM Printed onto Product, SAA Approval Certificate
Meets ESV Additional Testing & verification requirements for RCBOs and listed on ESV website

NE-RCBO
RCBO With Tail - Combines RCD+CB - C Curve

Blue Handle - C Curve
6, 10, 16, 20, 25, 32AMP
30mA Standard Tripping Current

Matching design for NE-CB
Designed for use inside Panel Boards with Busbar Chassis

Standard width per pole = 18mm

Main Purpose of item - Overload / Short Circuit & Earth Leakage Protection

RCM Printed onto Product, SAA Approval Certificate
Meets ESV Additional Testing & verification requirements because it in longer than 110mm in length

NE-RCBO
RCBO With Tail - Combines RCD+CB - D Curve

Black Handle - D Curve
10, 16, 20, 25, 32AMP
30mA Standard Tripping Current

Matching design for NE-CB
Designed for use inside Panel Boards with Busbar Chassis

Standard width per pole = 18mm

Main Purpose of item - Overload / Short Circuit & Earth Leakage Protection

RCM Printed onto Product, SAA Approval Certificate
Meets ESV Additional Testing & verification requirements because it in longer than 110mm in length

 

NE-RCBO3P
RCBO for 3phase - Combines RCD+CB - Coming Soon

6, 10, 16, 20, 25, 32, 40, 50, 63AMP
30mA Standard Tripping Current

Main Purpose of item - Overload / Short Circuit & Earth Leakage Protection

 

Accessories that match:

NE-LED
Indicator

Available in Red, White, Blue, Yellow, Green or
3Phase (Red, White, Blue)

Standard width per pole = 18mm

Main Purpose of item - Indicator Lights

NE-AC
Auxiliary Contact

Module added on Block

Standard width per pole = 18mm

Main Purpose of item - When the item it is connected to trips a warning lamp or other item can be wired in to alert you of the item tripping

NE-ST+AC
Shunt Trip + Auxiliary Contact

Module added on Block

Standard width per pole = 18mm

Main Purpose of item - To remotely trip the item it is connected to. Also has a built in Auxiliary Contact so when the item it is connected to trips a warning lamp or other item can be wired in to alert you of the item tripping.